Architen Landrell designs, engineers, makes and installs ETFE cushion roofs, atria, rooflights and facades. Every cushion is cut and welded in our factory in Chepstow, UK. ETFE weighs about 1% of the equivalent glass and lets through up to 95% of daylight, so it can cover huge spaces on a far lighter structure.

Reviewed by Guy Monkley, Head of Sales Updated October 2026

Munhak Aquatics Centre · Incheon, South Korea
Already have an ETFE roof? Maintenance, repairs and replacement
Overview

What is an ETFE roof?

An ETFE roof is made of ethylene tetrafluoroethylene foil, a tough, transparent plastic. The foil is usually formed into air-filled ETFE cushions, held in aluminium frames on a steel structure and kept inflated by a small air handling unit.

Two to four layers of foil give the insulation you need, and printed layers control sun and glare. The same cushions can roof an atrium, a pool or a stadium, or clad a whole building as an ETFE facade. Inflating a cushion puts the foil into tension and curves it in two directions, the same principle as an inflatable fabric structure; our guide to how tensile structures work explains why that double curvature matters.

Up to 95%
of daylight passes through, depending on the layers and foil thickness
About 1%
of the weight of equivalent glass
1.4 W/m²K
U-value of a 4-layer cushion
B-s1,d0
fire classification, EN 13501-1
100%
recyclable
3.5 m
cushion span one way, any length the other
The ETFE cushion tunnel that carries the Kelana Jaya LRT line between buildings in Kuala Lumpur, seen from below
ETFE facades and cladding

Malaysia’s first “tunnel in the air”

363 ETFE cushions, no two the same, wrap an elevated railway as it passes between a hotel and an apartment block. We fitted them from above while trains ran beneath.

Kelana Jaya LRT · Kuala Lumpur, Malaysia
What we build

ETFE cushion roofs, rooflights, canopies, domes and facades

Each of these can be built with air-filled ETFE cushions or a single tensioned layer of foil, designed around the building’s span, climate, daylight and energy targets.
  • ETFE cushion atrium roof at Aurora House, London, seen from below

    ETFE cushion roofs and atria

    Two, three or four-layer cushions over atria, courtyards, pools and covered streets, chosen for the span, daylight and insulation you need. At Aurora House in London, five three-layer cushions let in 70% of the light while controlling glare and heat.

  • Teardrop ETFE cushion rooflights set into the fabric roof of Kertajati Airport, West Java

    ETFE rooflights

    Cushions set into a larger roof to bring daylight deep into exhibition halls, terminals and arenas. At ExCeL London, each of the three rooflights covers 615 m², and their vents open to let out smoke in a fire, even without power.

  • Single-layer ETFE canopy over the footbridge at East Croydon Station

    ETFE canopies and walkways

    ETFE on a light frame or cable net covers walkways, transport hubs and the gaps between buildings. Single-layer canopies need no air supply, cost less than cushions and stay clean because dirt does not stick to the foil, as at East Croydon Station.

  • Fritted ETFE pillow dome at Nova Hreod Academy, Swindon

    ETFE domes and freeform roofs

    Every cushion is patterned individually, so ETFE can follow domes, curves and sculptural shapes that would be hard to glaze. South Quarter in Jakarta, Indonesia’s first ETFE cushion roof, is a dome of 212 printed cushions.

  • ETFE cushion cladding on the Kelana Jaya LRT tunnel in Kuala Lumpur, seen from above

    ETFE facades and cladding

    Cushions can wrap a building or structure in a light, translucent skin. The Kelana Jaya LRT tunnel in Kuala Lumpur uses 363 cushions, no two the same. For fabric and mesh facades, see Facade cladding.

  • Moving roofs

    Need an ETFE roof that opens?

    Retractable and moving ETFE roofs, drives and controls are covered on their own page.

    Retractable roofs
ETFE systems

How ETFE roofs work

Every ETFE roof, canopy or facade is built one of two ways: a single tensioned layer of foil, or air-filled cushions of two to four layers. More layers trap more air, so the roof holds in more heat.

Single layer

about 5.9 W/m²K
Cross-section of single-layer ETFE: one sheet of foil tensioned over a steel arch, frame or cable net, with no air supply.

One tensioned sheet on a steel frame, arch or cable net. It needs no air supply, is quick to install and costs less than cushions, which suits canopies, walkways and covered streets, as at East Croydon Station.

2-layer cushion

2.9 W/m²K
Cross-section of a 2-layer ETFE cushion: a printed outer layer and a clear inner layer with one air chamber, clamped in aluminium frames and fed with air at 200 to 300 Pa.

One air chamber. The lightest, clearest cushion, used where daylight matters most, as at the Leicester City FC Training Ground.

3-layer cushion

1.9 W/m²K
Cross-section of a 3-layer ETFE cushion: printed outer layer, clear middle and inner layers, two air chambers.

Two air chambers cut heat loss by about 34% compared with two layers. Used at Marwell Zoo to hold a tropical climate.

4-layer cushion

1.4 W/m²K
Cross-section of a 4-layer ETFE cushion: printed outer layer, two clear middle layers and a clear inner layer, three air chambers.

Three air chambers give the best insulation of any ETFE build-up, for buildings with tight energy targets.

The outer layer is usually printed (fritted) to control sun; inner layers are clear. Source: Architen Landrell, ETFE System Guide to Design.

Printing on ETFE (fritting)

Nearly every ETFE roof we build has a printed outer layer. A pattern in silver ink on the underside of the top foil reflects light and heat before they reach the space below.

  • Less glare and overheating, so the space stays comfortable
  • Light level set to suit, from 85% down to 20%
  • Helps meet daylight and solar gain (G-value) targets
  • Patterns too fine to notice from a few metres away, or bold graphics in colour, like the batik prints at South Quarter and the peacock feathers at Kertajati Airport
  • Intelligent Printing: printed layers that move with air pressure to change the shading through the day, as at Barts Hospital
Light print
Light print
Medium print
Medium print
Dense print
Dense print
More daylight 85% to 20% light through More shade

System options

Every cushion roof has an air handling unit. Ventilation and rain noise suppression are added to suit.

  • Air handling unit

    Every cushion roof is kept inflated by our own air handling unit. One unit serves up to 2,500 m² of roof and uses less than 60 W in normal running. Two fans take turns, and both run if the pressure drops. Options include a weather station that adjusts the pressure for wind and snow, remote monitoring with email and SMS alerts, and battery backup.

    Data sheet (PDF)
  • Ventilation

    Hinged ETFE panels open for fresh air, to release heat or to clear smoke. They can be opened by a switch or the building management system, or automatically by weather sensors, timers or smoke detectors. At ExCeL London the rooflight vents open even without power.

    Data sheet (PDF)
  • Rain noise suppression

    An air-filled cushion can drum in heavy rain. A mesh over the cushions stops the reverberation and cuts the noise by up to 10 decibels, which matters over pools, libraries and quiet workspaces, as at Winchester Sport & Leisure Park.

    Data sheet (PDF)
Performance

ETFE foil performance data

ETFE foil performance data
Property Value
Light transmission, single layer 90 to 95%
UV transmission, 320 to 380 nm 83 to 88%
Fire classification B-s1,d0 (EN 13501-1) · B1 (DIN 4102)
Cushion inflation pressure 200 to 300 Pa
Air handling unit power Under 60 W running, 100 W maximum
Roof area per air handling unit Up to 2,500 m²
Holds pressure after a power cut 3 to 6 hours
Maximum cushion span 3.5 m one way, any length the other
Expected life More than 30 years
Foil cleaning Every 2 to 3 years
Warranty 5 years standard, 10 years available

Source: Architen Landrell, ETFE System Guide to Design.

An Architen Landrell technician working on top of an ETFE cushion roof
Maintenance & repairs

Already have an ETFE roof?

We inspect, service, repair and replace ETFE cushion roofs, including roofs built by other companies. Our maintenance team carries out planned and emergency work on sites around the world.

  • Inspections and condition surveys
  • Air handling unit servicing and testing
  • Repairs to holes and tears in the foil
  • Foil cleaning
  • New cushions fitted to the existing structure
  • Upgrades for more daylight or less heat

Maintenance team: +44 (0) 1291 638 200 · maintenance@architen.com

For architects and clients

Planning and specifying an ETFE roof

The earlier we are involved, the lighter the structure and the simpler the details. These are the questions our engineers will ask, so it helps to have a view on them.

  1. What will the roof cover?

    An atrium, courtyard, pool, covered street or stadium, and roughly how big it is.
  2. Cushions or a single layer?

    Cushions insulate and need an air supply; a single tensioned layer needs none and costs less, which suits canopies and walkways.
  3. How much light, heat and glare?

    Two, three or four layers set the insulation, and a printed outer layer sets the light, from 85% down to 20%.
  4. The supporting structure

    New or existing steel, glulam or a cable net. A cushion spans up to about 3.5 m one way and any length the other.
  5. Air, ventilation and smoke

    Where the air handling unit goes and its power supply, and whether hinged panels must open for fresh air or smoke.
  6. Rain noise and drainage

    A rain noise suppression mesh over pools, libraries and quiet spaces, and gutters for the rainwater.
  7. Access and maintenance

    How the roof will be reached to clean the foil every 2 to 3 years and service the air handling unit twice a year.
Cutting table in the Architen Landrell factory in Chepstow
How we deliver

A UK ETFE manufacturer, from first sketch to maintenance

We design, engineer, make, install and maintain every system ourselves, with steelwork from our group company, Metafab Structures.

Since 1982
designing and building tensile structures
In-house
design, manufacture, installation and maintenance
6 continents
where our structures stand
100,000 m²
of ETFE we can make each year in Chepstow
FAQs

ETFE roof questions

Can’t see your question? Ask an engineer.
How long does an ETFE roof last?

ETFE foil resists UV light, extreme temperatures and air pollution. It has a design life of more than 30 years.

How much lighter is ETFE than glass?

About 1% of the weight of the equivalent glass, so the supporting structure can be lighter and spans larger.

Can you repair or replace an ETFE roof built by another company?

Yes. At the University of Hertfordshire we replaced an ETFE roof installed by others nearly 20 years earlier, adapting our clamping system to fit the existing structure.

What happens to an ETFE roof in a power cut?

Cushions hold their pressure for 3 to 6 hours without power. The air handling unit uses less than 60 W in normal running, and an optional battery backup can keep it running for up to an hour.

Is ETFE noisy in the rain?

Rain can drum on an air-filled cushion. A rain noise suppression mesh over the cushions stops it.

Is ETFE safe in a fire?

ETFE foil is classified B-s1,d0 to EN 13501-1 and B1 to DIN 4102. Hinged ETFE panels can also open for smoke ventilation.

How often does an ETFE roof need maintenance?

We recommend cleaning the foil every 2 to 3 years and servicing the air handling unit twice a year.

Can ETFE be recycled?

Yes. ETFE is a thermoplastic, so it can be melted down and reprocessed several times without significant loss of properties.

How much does an ETFE roof cost?

It depends on the material, the design and how long it takes to make, so we don’t publish a budget price per m²: a single figure could be misleading. Send us drawings or a sketch and we will price your project.

Talk to an engineer

Planning an ETFE roof, or looking after one?

Send us a sketch, drawings, photos or a short description and one of our engineers will come back to you.

+44 (0) 1291 638 200 mail@architen.com Architen Landrell, Station Road, Chepstow, NP16 5PF, UK

"(Required)" indicates required fields

Your enquiry is about(Required)
Accepted file types: jpg, jpeg, png, gif, pdf, dwg, dxf, Max. file size: 128 MB.
Call us Enquire